The Faratel Isolated Transformer is a device whose main function is to create complete isolation between the input phase/null and the outlet phase/null and remove Common Mode noise, and it is also possible to install in electrical isolation in medical applications.
23100000 Toman 21021000 Toman
Add_cart
Tags:
Add to favorites
Add to comparison list
Technical description
Product Specifications
User comments ( 0 )

The Faratel Isolated Transformer is a device whose main function is to create complete isolation between the input phase/nozzle and the outlet phase/nozzle to eliminate Common Mode noise, and it is also possible to install in an electrically isolated form in medical applications, in which case the terminal of the outlet nozzle is not connected to the earth.

Isolated trans devices have the ability to connect to the output of Faratel UPS. In summary, the benefits of using isolated transformers in the UPS output are as follows:

– Significant reduction of Common Mode Noise in the UPS output, which allows the use of UPS with noise-sensitive equipment. By using an isolated transformer, it is possible to connect the outlet nozzle to the earth and thus the common mode noise is filtered.

– The ability to feed loads that transiently draw DC currents from the UPS.

– The possibility of removing the limitations of the electricity distribution network, which in some areas causes the voltage of the nozzle to increase compared to the earth and causes disruption in sensitive equipment.

Despite the advantages of using an isolated transformer in the UPS output, the use of an isolated transformer also causes some limitations, the most important of which are reducing the quality of the output waveform in feeding computer loads, occupying space, and reducing the output efficiency, but Faratel transformers are designed in such a way that they have significantly eliminated these limitations. In terms of space occupancy, insulated transformers can be installed in the rack as well as under the UPS, in which case it only increases the height and does not occupy any space. In the design of Faratel UPS, the installation of an isolated transformer at the output is considered, and for this purpose, a special ITR connector is installed on the back of the UPS to which the isolated trans ITR cable is connected, and thus the limitations caused by the loss of quality and regulation and the isolated trans are significantly improved by the UPS. Therefore, it is recommended to use Faratel isolated transformers with its compatible UPS.